Libbiosig Project maintains a specialized biomedical signal-processing library that, despite a narrow product focus, sits in the software supply chain of medical device firmware and signal-analysis applications where it handles untrusted input from patient monitors and diagnostic equipment. Vulnerabilities affecting this library skew strongly toward critical-severity outcomes, driven by a recurring pattern of memory-safety weaknesses including stack-based and heap-based buffer overflows, integer overflows, and double-free conditions that are characteristic of C-based signal-parsing code. The concentration of critical flaws in a single, embedded component means that a single vulnerability can propagate across all downstream medical and diagnostic devices that link the library, amplifying the severity impact relative to the modest disclosure volume. Defenders should prioritize inventory and patching of medical devices incorporating this library as a matter of patient-safety risk management. Current exploitation activity and exposure counts are shown alongside this summary.
The number and severity of CVEs published that impact products developed by Libbiosig Project over time
Signals from CVEs in this vendor scope (41 CVEs).
41 CVEs · Highest risk first
| CVE | Published | CVSS | Risk | KEV | Exploit |
|---|---|---|---|---|---|
CVE-2025-66043CRITICAL Several stack-based buffer overflow vulnerabilities exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.1. A specially crafted MFER file can lead to arbitr | Dec 11, 2025 | 9.8 | 34 | NO | NO |
CVE-2025-54492CRITICAL A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER fi | Aug 25, 2025 | 9.8 | 34 | NO | NO |
CVE-2025-54491CRITICAL A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER fi | Aug 25, 2025 | 9.8 | 34 | NO | NO |
CVE-2025-54489CRITICAL A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER fi | Aug 25, 2025 | 9.8 | 34 | NO | NO |
CVE-2025-54485CRITICAL A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER fi | Aug 25, 2025 | 9.8 | 34 | NO | NO |
CVE-2025-54484CRITICAL A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER fi | Aug 25, 2025 | 9.8 | 34 | NO | NO |
CVE-2025-54483CRITICAL A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER fi | Aug 25, 2025 | 9.8 | 34 | NO | NO |
CVE-2025-54482CRITICAL A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER fi | Aug 25, 2025 | 9.8 | 34 | NO | NO |
CVE-2025-54481CRITICAL A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER fi | Aug 25, 2025 | 9.8 | 34 | NO | NO |
CVE-2025-54480CRITICAL A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER fi | Aug 25, 2025 | 9.8 | 34 | NO | NO |
Signals from CVEs in this vendor scope (41 CVEs).