Predictive Vulnerability Intelligence.

Product

  • Product
  • Pricing
  • Documentation

Company

  • About
  • Partnerships
  • Blog
  • Support

Legal

  • Terms
  • Privacy
  • Data Licensing

© 2026 FAUCET Technologies LLC. All rights reserved.

Technostrobe

First CVE: Apr 5, 2026Active for: 1 yearTotal CVEs: 6

Technostrobe's vulnerability profile centers on a narrowly scoped product line centered around the HI-LED WR120 G2 networked lighting control device and its firmware. Vulnerabilities affecting this vendor skew strongly toward critical-severity outcomes and recur through a consistent set of access-control and authentication weaknesses—improper access control, missing authorization, CSRF, exposure of sensitive information, and improper authentication—that are characteristic of insufficiently hardened embedded web interfaces. Defenders managing these devices should prioritize firmware updates and restrict network access; current severity and exposure counts are shown alongside this summary.

FAUCET AI Generated
6
Total CVEs
More Total CVEs than 86% of tracked vendors
3.0
Avg CVEs / Product / Year
More Avg CVEs / Product / Year than 91% of tracked vendors
8.4
Avg CVSS Score
Higher Avg CVSS Score than 81% of tracked vendors
0.0%
In CISA KEV
Bottom 1%

Trends Over Time

The number and severity of CVEs published that impact products developed by Technostrobe over time

Volume of CVEsAvg CVSS Base Score
First CVE
Apr 5, 2026
3 months ago
Most Recent CVE
Apr 5, 2026
110 days ago

Products(2 total)

Top CVEs

Signals from CVEs in this vendor scope (6 CVEs).

6 CVEs · Highest risk first

CVEPublishedCVSSRiskKEVExploit
CVE-2026-5573CRITICAL
A weakness has been identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This impacts an unknown function of the file /fs. Executing a manipulation of the argument cwd can l
Apr 5, 20269.831NONO
CVE-2026-5570CRITICAL
A vulnerability was determined in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. The affected element is the function index_config of the file /LoginCB. This manipulation causes imp
Apr 5, 20269.831NONO
CVE-2026-5569CRITICAL
A vulnerability was found in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. Impacted is an unknown function of the file /Technostrobe/ of the component Endpoint. The manipulation re
Apr 5, 20269.831NONO
CVE-2026-5574CRITICAL
A security vulnerability has been detected in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. Affected is the function deletefile of the component FsBrowseClean. The manipulation of
Apr 5, 20269.130NONO
CVE-2026-5571HIGH
A vulnerability was identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. The impacted element is an unknown function of the file /fs of the component Configuration Data Hand
Apr 5, 20267.526NONO
CVE-2026-5572MEDIUM
A security flaw has been discovered in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This affects an unknown function. Performing a manipulation results in cross-site request forge
Apr 5, 20264.319NONO
View all 6 CVEs →

CVE Severity & Scoring

Severity distribution of CVEs that affect this vendor's products6 CVEs
17%
17%
67%
Severity distribution among all CVEs352,231 CVEs
45%
40%
11%
MediumHighCritical
Attack Vector
Local0 (0.0%)
Network6 (100.0%)
Unknown0 (0.0%)
Physical0 (0.0%)
Adjacent Network0 (0.0%)
Attack Complexity
Low6 (100.0%)
High0 (0.0%)
Unknown0 (0.0%)
User Interaction
None5 (83.3%)
Unknown0 (0.0%)
Required1 (16.7%)
Privileges Required
Low0 (0.0%)
High0 (0.0%)
None6 (100.0%)
Unknown0 (0.0%)

Exploit Exposure

Signals from CVEs in this vendor scope (6 CVEs).

CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
0 CVEs
0.0% of CVEs· Bottom 1%

Social Chatter

An overview of all social media posts that mention a CVE ID that affects a product developed by Technostrobe.

Media Mentions

Media articles that mention a CVE ID that affects a product developed by Technostrobe — matched by CVE ID, not by vendor name.

Top CNAs Publishing CVEs For Technostrobe's Products

View all 1 CNAs →

Top CWEs