Primasystems develops FlexAir, a modestly represented but prominent web-based infrastructure management product whose vulnerability profile skews strongly toward critical-severity outcomes and frequently acquires public exploit code. The durable signal across disclosures centers on application-layer weaknesses endemic to web interfaces: unrestricted file uploads, cross-site request forgery, improper authentication, cross-site scripting, and OS command injection, reflecting risks that arise when administrative interfaces lack robust input validation and request integrity controls. Defenders should prioritize patching this vendor's advisories and restrict network access to management interfaces; current severity, exploitation, and exposure counts are shown alongside this summary.
The number and severity of CVEs published that impact products developed by Primasystems over time
Signals from CVEs in this vendor scope (10 CVEs).
10 CVEs · Highest risk first
| CVE | Published | CVSS | Risk | KEV | Exploit |
|---|---|---|---|---|---|
CVE-2019-7669HIGH Prima Systems FlexAir, Versions 2.3.38 and prior. Improper validation of file extensions when uploading files could allow a remote authenticated attacker to upload and execute mali | Jul 1, 2019 | 8.8 | 45 | NO | NO |
CVE-2019-7670HIGH Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream | Jul 1, 2019 | 7.2 | 44 | NO | YES |
CVE-2019-7666HIGH Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access t | Jul 1, 2019 | 8.8 | 39 | NO | YES |
CVE-2019-9189HIGH Prima Systems FlexAir, Versions 2.4.9api3 and prior. The application allows the upload of arbitrary Python scripts when configuring the main central controller. These scripts can b | Jun 5, 2019 | 8.8 | 37 | NO | YES |
CVE-2019-7671CRITICAL Prima Systems FlexAir, Versions 2.3.38 and prior. Parameters sent to scripts are not properly sanitized before being returned to the user, which may allow an attacker to execute ar | Jun 5, 2019 | 9.0 | 35 | NO | YES |
CVE-2019-7667CRITICAL Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the datab | Jul 1, 2019 | 9.8 | 31 | NO | NO |
CVE-2019-7668CRITICAL Prima Systems FlexAir devices have Default Credentials. | Jul 1, 2019 | 9.8 | 29 | NO | NO |
CVE-2019-7672HIGH Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to e | Jun 5, 2019 | 8.8 | 27 | NO | NO |
CVE-2019-7281HIGH Prima Systems FlexAir, Versions 2.3.38 and prior. An unauthenticated user can send unverified HTTP requests, which may allow the attacker to perform certain actions with administra | Jul 1, 2019 | 8.8 | 22 | NO | NO |
CVE-2019-7280HIGH Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a val | Jul 1, 2019 | 8.8 | 22 | NO | NO |
Signals from CVEs in this vendor scope (10 CVEs).
An overview of all social media posts that mention a CVE ID that affects a product developed by Primasystems.
Media articles that mention a CVE ID that affects a product developed by Primasystems — matched by CVE ID, not by vendor name.