Predictive Vulnerability Intelligence.

Product

  • Product
  • Pricing
  • Documentation

Company

  • About
  • Partnerships
  • Blog
  • Support

Legal

  • Terms
  • Privacy
  • Data Licensing

© 2026 FAUCET Technologies LLC. All rights reserved.

Panorama Project

First CVE: Dec 31, 2020Active for: 6 yearsTotal CVEs: 5

The Panorama Project maintains a focused healthcare interoperability adapter product, NHIS Servis iSign Adapter, where the observed vulnerability pattern centers on URL-redirection logic. This application-layer weakness class is characteristic of web-facing integration tools that broker authentication and data flows across healthcare systems; current severity, exploitation, and exposure counts are shown alongside this summary.

FAUCET AI Generated
5
Total CVEs
More Total CVEs than 56% of tracked vendors
5.0
Avg CVEs / Product / Year
More Avg CVEs / Product / Year than 80% of tracked vendors
8.4
Avg CVSS Score
Higher Avg CVSS Score than 56% of tracked vendors
0.0%
In CISA KEV
Bottom 1%

Trends Over Time

The number and severity of CVEs published that impact products developed by Panorama Project over time

Volume of CVEsAvg CVSS Base Score
First CVE
Dec 31, 2020
5 years ago
Most Recent CVE
Dec 31, 2020
2,031 days ago

Products(1 total)

Top CVEs

Signals from CVEs in this vendor scope (5 CVEs).

5 CVEs · Highest risk first

CVEPublishedCVSSRiskKEVExploit
CVE-2020-25844CRITICAL
The digest generation function of NHIServiSignAdapter has not been verified for parameter’s length, which leads to a stack overflow loophole. Remote attackers can use the leak to e
Dec 31, 20209.829NONO
CVE-2020-25843CRITICAL
NHIServiSignAdapter fails to verify the length of digital credential files’ path which leads to a heap overflow loophole. Remote attackers can use the leak to execute code without
Dec 31, 20209.828NONO
CVE-2020-25845HIGH
Multiple functions of NHIServiSignAdapter failed to verify the users’ file path, which leads to the SMB request being redirected to a malicious host, resulting in the leakage of us
Dec 31, 20207.423NONO
CVE-2020-25846HIGH
The digest generation function of NHIServiSignAdapter has not been verified for source file path, which leads to the SMB request being redirected to a malicious host, resulting in
Dec 31, 20207.422NONO
CVE-2020-25842HIGH
The encryption function of NHIServiSignAdapter fail to verify the file path input by users. Remote attacker can access arbitrary files through the flaw without privilege.
Dec 31, 20207.522NONO
View all 5 CVEs →

CVE Severity & Scoring

Severity distribution of CVEs that affect this vendor's products5 CVEs
60%
40%
Severity distribution among all CVEs352,231 CVEs
45%
40%
11%
HighCritical
Attack Vector
Local0 (0.0%)
Network5 (100.0%)
Unknown0 (0.0%)
Physical0 (0.0%)
Adjacent Network0 (0.0%)
Attack Complexity
Low5 (100.0%)
High0 (0.0%)
Unknown0 (0.0%)
User Interaction
None3 (60.0%)
Unknown0 (0.0%)
Required2 (40.0%)
Privileges Required
Low0 (0.0%)
High0 (0.0%)
None5 (100.0%)
Unknown0 (0.0%)

Exploit Exposure

Signals from CVEs in this vendor scope (5 CVEs).

CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
0 CVEs
0.0% of CVEs· Bottom 1%

Social Chatter

An overview of all social media posts that mention a CVE ID that affects a product developed by Panorama Project.

Media Mentions

Media articles that mention a CVE ID that affects a product developed by Panorama Project — matched by CVE ID, not by vendor name.

Top CNAs Publishing CVEs For Panorama Project's Products

View all 1 CNAs →

Top CWEs