Predictive Vulnerability Intelligence.

Product

  • Product
  • Pricing
  • Documentation

Company

  • About
  • Partnerships
  • Blog
  • Support

Legal

  • Terms
  • Privacy
  • Data Licensing

© 2026 FAUCET Technologies LLC. All rights reserved.

Intellicom

First CVE: Dec 30, 2009Active for: 17 yearsTotal CVEs: 6

Intellicom's vulnerability profile centers on a specialized line of industrial-control and remote-access products including its NetBiter WebSCADA and EasyConnect gateway appliances, which span edge-networking and protocol-bridging roles in operational-technology environments. The recurring weakness classes—path traversal, code injection, and buffer-boundary issues—reflect the parsing and access-control demands of these devices, and public exploit code has a history of becoming available for vulnerabilities in this product family. Current severity and exploitation figures are shown alongside this summary.

FAUCET AI Generated
6
Total CVEs
More Total CVEs than 86% of tracked vendors
0.3
Avg CVEs / Product / Year
More Avg CVEs / Product / Year than 3% of tracked vendors
8.8
Avg CVSS Score
Higher Avg CVSS Score than 84% of tracked vendors
0.0%
In CISA KEV
Bottom 1%

Trends Over Time

The number and severity of CVEs published that impact products developed by Intellicom over time

Volume of CVEsAvg CVSS Base Score
First CVE
Dec 30, 2009
16 years ago
Most Recent CVE
Feb 15, 2011
5,638 days ago

Products(9 total)

Top CVEs

Signals from CVEs in this vendor scope (6 CVEs).

6 CVEs · Highest risk first

CVEPublishedCVSSRiskKEVExploit
CVE-2009-4462HIGH
Stack-based buffer overflow in the NetBiterConfig utility (NetBiterConfig.exe) 1.3.0 for Intellicom NetBiter WebSCADA allows remote attackers to execute arbitrary code via a long h
Dec 30, 200910.047NOYES
CVE-2010-4733HIGH
WebSCADA WS100 and WS200, Easy Connect EC150, Modbus RTU - TCP Gateway MB100, and Serial Ethernet Server SS100 on the IntelliCom NetBiter NB100 and NB200 platforms have a default u
Feb 15, 201110.029NONO
CVE-2010-4732HIGH
cgi-bin/read.cgi in WebSCADA WS100 and WS200, Easy Connect EC150, Modbus RTU - TCP Gateway MB100, and Serial Ethernet Server SS100 on the IntelliCom NetBiter NB100 and NB200 platfo
Feb 15, 20119.028NONO
CVE-2009-4463HIGH
Intellicom NetBiter WebSCADA devices use default passwords for the HICP network configuration service, which makes it easier for remote attackers to modify network settings and cau
Dec 30, 200910.027NONO
CVE-2010-4730MEDIUM
Directory traversal vulnerability in cgi-bin/read.cgi in WebSCADA WS100 and WS200, Easy Connect EC150, Modbus RTU - TCP Gateway MB100, and Serial Ethernet Server SS100 on the Intel
Feb 15, 20116.822NONO
CVE-2010-4731MEDIUM
Absolute path traversal vulnerability in cgi-bin/read.cgi in WebSCADA WS100 and WS200, Easy Connect EC150, Modbus RTU - TCP Gateway MB100, and Serial Ethernet Server SS100 on the I
Feb 15, 20116.821NONO
View all 6 CVEs →

CVE Severity & Scoring

Severity distribution of CVEs that affect this vendor's products6 CVEs
33%
67%
Severity distribution among all CVEs352,294 CVEs
45%
40%
11%
MediumHigh
Attack Vector
Local0 (0.0%)
Network0 (0.0%)
Unknown6 (100.0%)
Physical0 (0.0%)
Adjacent Network0 (0.0%)
Attack Complexity
Low0 (0.0%)
High0 (0.0%)
Unknown6 (100.0%)
User Interaction
None0 (0.0%)
Unknown6 (100.0%)
Required0 (0.0%)
Privileges Required
Low0 (0.0%)
High0 (0.0%)
None0 (0.0%)
Unknown6 (100.0%)

Exploit Exposure

Signals from CVEs in this vendor scope (6 CVEs).

CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
1 CVE
16.7% of CVEs· 77th percentile

Social Chatter

An overview of all social media posts that mention a CVE ID that affects a product developed by Intellicom.

Media Mentions

Media articles that mention a CVE ID that affects a product developed by Intellicom — matched by CVE ID, not by vendor name.

Top CNAs Publishing CVEs For Intellicom's Products

View all 1 CNAs →

Top CWEs