Integrated Lights Out 5
Vendor:
First CVE: Jan 5, 2021 · Active for 5 years
12
Total CVEs
More Total CVEs than 91% of tracked products
6.0
Avg CVEs / Year
Higher CVE frequency than 91% of tracked products
5.0
Avg CVSS
Higher Avg CVSS than 11% of tracked products
0.0%
KEV Rate
Bottom 1%
Trends Over Time
The number and severity of CVEs published that impact Integrated Lights Out 5 over time
Volume of CVEsAvg CVSS Base Score
First CVE
Jan 5, 2021
5 years ago
Most Recent CVE
Mar 22, 2023
1,224 days ago
CVE Severity & Scoring
Integrated Lights Out 512 CVEs
100%
All CVEs353,240 CVEs
45%
40%
11%
Medium
Attack Vector
Local1 (8.3%)
Network11 (91.7%)
Unknown0 (0.0%)
Physical0 (0.0%)
Adjacent Network0 (0.0%)
Attack Complexity
Low12 (100.0%)
High0 (0.0%)
Unknown0 (0.0%)
User Interaction
None2 (16.7%)
Unknown0 (0.0%)
Required10 (83.3%)
Privileges Required
Low1 (8.3%)
High10 (83.3%)
None1 (8.3%)
Unknown0 (0.0%)
Top CVEs
Signals from CVEs in this product scope (12 CVEs).
12 CVEs · Highest risk first
| CVE | Published | CVSS | Risk | KEV | Exploit |
|---|---|---|---|---|---|
CVE-2021-29202MEDIUM A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE | May 25, 2021 | 6.7 | 21 | NO | NO |
CVE-2023-28083MEDIUM A remote Cross-site Scripting vulnerability was discovered in HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). HPE has prov | Mar 22, 2023 | 5.4 | 19 | NO | NO |
CVE-2021-29210MEDIUM A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Ser | May 25, 2021 | 4.8 | 18 | NO | NO |
CVE-2021-29209MEDIUM A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Ser | May 25, 2021 | 4.8 | 18 | NO | NO |
CVE-2021-29208MEDIUM A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Ser | May 25, 2021 | 4.8 | 18 | NO | NO |
CVE-2021-29206MEDIUM A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity | May 25, 2021 | 4.8 | 18 | NO | NO |
CVE-2021-29205MEDIUM A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity | May 25, 2021 | 4.8 | 18 | NO | NO |
CVE-2021-29204MEDIUM A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity | May 25, 2021 | 4.8 | 18 | NO | NO |
CVE-2021-29201MEDIUM A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity | May 25, 2021 | 4.8 | 18 | NO | NO |
CVE-2021-29211MEDIUM A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity | May 25, 2021 | 4.8 | 17 | NO | NO |
Exploit Exposure
Signals from CVEs in this product scope (12 CVEs).
CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
0 CVEs
0.0% of CVEs· Bottom 1%
Social Chatter
Signals from CVEs in this product scope (12 CVEs).
Media Mentions
Signals from CVEs in this product scope (12 CVEs).
Top CNAs Publishing CVEs For Integrated Lights Out 5
Top CWEs
Versions
No cataloged versions.