Multilin D60

Vendor:

First CVE: Mar 23, 2022 · Active for 4 years

6
Total CVEs
More Total CVEs than 80% of tracked products
6.0
Avg CVEs / Year
Higher CVE frequency than 90% of tracked products
7.3
Avg CVSS
Higher Avg CVSS than 46% of tracked products
0.0%
KEV Rate
Bottom 1%

Trends Over Time

The number and severity of CVEs published that impact Multilin D60 over time

Volume of CVEsAvg CVSS Base Score
First CVE
Mar 23, 2022
4 years ago
Most Recent CVE
Mar 23, 2022
1,584 days ago

CVE Severity & Scoring

Multilin D606 CVEs
All CVEs352,231 CVEs
MediumHighCritical
Attack Vector
Local0 (0.0%)
Network6 (100.0%)
Unknown0 (0.0%)
Physical0 (0.0%)
Adjacent Network0 (0.0%)
Attack Complexity
Low6 (100.0%)
High0 (0.0%)
Unknown0 (0.0%)
User Interaction
None5 (83.3%)
Unknown0 (0.0%)
Required1 (16.7%)
Privileges Required
Low0 (0.0%)
High0 (0.0%)
None6 (100.0%)
Unknown0 (0.0%)

Top CVEs

Signals from CVEs in this product scope (6 CVEs).

6 CVEs · Highest risk first

CVEPublishedCVSSRiskKEVExploit
GE UR IED firmware versions prior to version 8.1x with “Basic” security variant does not allow the disabling of the “Factory Mode,” which is used for servicing the IED by a “Factor
Mar 23, 20229.831NONO
GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool – Enervista UR Setup. This UR Setup tool validates the authenticity
Mar 23, 20229.830NONO
GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication.
Mar 23, 20227.524NONO
GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-si
Mar 23, 20226.121NONO
GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a “Last-key pressed” MODBUS register can be used to ga
Mar 23, 20225.320NONO
GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unrespons
Mar 23, 20225.320NONO

Exploit Exposure

Signals from CVEs in this product scope (6 CVEs).

CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
0 CVEs
0.0% of CVEs· Bottom 1%

Social Chatter

Signals from CVEs in this product scope (6 CVEs).

Media Mentions

Signals from CVEs in this product scope (6 CVEs).

Top CNAs Publishing CVEs For Multilin D60

Top CWEs

Versions

No cataloged versions.