Multilin D60
Vendor:
First CVE: Mar 23, 2022 · Active for 4 years
6
Total CVEs
More Total CVEs than 80% of tracked products
6.0
Avg CVEs / Year
Higher CVE frequency than 90% of tracked products
7.3
Avg CVSS
Higher Avg CVSS than 46% of tracked products
0.0%
KEV Rate
Bottom 1%
Trends Over Time
The number and severity of CVEs published that impact Multilin D60 over time
Volume of CVEsAvg CVSS Base Score
First CVE
Mar 23, 2022
4 years ago
Most Recent CVE
Mar 23, 2022
1,584 days ago
CVE Severity & Scoring
Multilin D606 CVEs
50%
17%
33%
All CVEs352,231 CVEs
45%
40%
11%
MediumHighCritical
Attack Vector
Local0 (0.0%)
Network6 (100.0%)
Unknown0 (0.0%)
Physical0 (0.0%)
Adjacent Network0 (0.0%)
Attack Complexity
Low6 (100.0%)
High0 (0.0%)
Unknown0 (0.0%)
User Interaction
None5 (83.3%)
Unknown0 (0.0%)
Required1 (16.7%)
Privileges Required
Low0 (0.0%)
High0 (0.0%)
None6 (100.0%)
Unknown0 (0.0%)
Top CVEs
Signals from CVEs in this product scope (6 CVEs).
6 CVEs · Highest risk first
| CVE | Published | CVSS | Risk | KEV | Exploit |
|---|---|---|---|---|---|
CVE-2021-27426CRITICAL GE UR IED firmware versions prior to version 8.1x with “Basic” security variant does not allow the disabling of the “Factory Mode,” which is used for servicing the IED by a “Factor | Mar 23, 2022 | 9.8 | 31 | NO | NO |
CVE-2021-27428CRITICAL GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool – Enervista UR Setup. This UR Setup tool validates the authenticity | Mar 23, 2022 | 9.8 | 30 | NO | NO |
CVE-2021-27422HIGH GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication. | Mar 23, 2022 | 7.5 | 24 | NO | NO |
CVE-2021-27418MEDIUM GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-si | Mar 23, 2022 | 6.1 | 21 | NO | NO |
CVE-2021-27424MEDIUM GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a “Last-key pressed” MODBUS register can be used to ga | Mar 23, 2022 | 5.3 | 20 | NO | NO |
CVE-2021-27420MEDIUM GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unrespons | Mar 23, 2022 | 5.3 | 20 | NO | NO |
Exploit Exposure
Signals from CVEs in this product scope (6 CVEs).
CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
0 CVEs
0.0% of CVEs· Bottom 1%
Social Chatter
Signals from CVEs in this product scope (6 CVEs).
Media Mentions
Signals from CVEs in this product scope (6 CVEs).
Top CNAs Publishing CVEs For Multilin D60
Top CWEs
Versions
No cataloged versions.