Total CVEs
More Total CVEs than 96% of tracked products
6.0
Avg CVEs / Year
Higher CVE frequency than 90% of tracked products
7.3
Avg CVSS
Higher Avg CVSS than 46% of tracked products
0.0%
KEV Rate
Bottom 1%

Trends Over Time

The number and severity of CVEs published that impact Control Win Sl over time

Volume of CVEsAvg CVSS Base Score
First CVE
Jan 29, 2019
7 years ago
Most Recent CVE
Dec 1, 2025
235 days ago

CVE Severity & Scoring

Control Win Sl30 CVEs
All CVEs352,294 CVEs
MediumHighCritical
Attack Vector
Local1 (3.3%)
Network28 (93.3%)
Unknown0 (0.0%)
Physical0 (0.0%)
Adjacent Network1 (3.3%)
Attack Complexity
Low30 (100.0%)
High0 (0.0%)
Unknown0 (0.0%)
User Interaction
None30 (100.0%)
Unknown0 (0.0%)
Required0 (0.0%)
Privileges Required
Low21 (70.0%)
High0 (0.0%)
None9 (30.0%)
Unknown0 (0.0%)

Top CVEs

Signals from CVEs in this product scope (30 CVEs).

30 CVEs · Highest risk first

CVEPublishedCVSSRiskKEVExploit
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which coul
Jan 29, 20199.831NONO
CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.
Aug 3, 20219.830NONO
In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the de
Mar 23, 20238.827NONO
A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file
Apr 7, 20228.127NONO
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access
Aug 3, 20238.825NONO
A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtim
Apr 7, 20227.525NONO
The SysDrv3S driver in the CODESYS Control runtime system on Microsoft Windows allows any system user to read and write within restricted memory space.
Apr 7, 20227.825NONO
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.
Feb 19, 20197.525NONO
An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTrac
Apr 7, 20227.124NONO
In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties.
Aug 3, 20217.524NONO

Exploit Exposure

Signals from CVEs in this product scope (30 CVEs).

CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
0 CVEs
0.0% of CVEs· Bottom 1%

Social Chatter

Signals from CVEs in this product scope (30 CVEs).

Media Mentions

Signals from CVEs in this product scope (30 CVEs).

Top CNAs Publishing CVEs For Control Win Sl

Top CWEs

Versions

No cataloged versions.