Cpp13 Firmware8 CVEs
All CVEs352,294 CVEs
MediumHighCritical
Attack Vector
Local0 (0.0%)
Network8 (100.0%)
Unknown0 (0.0%)
Physical0 (0.0%)
Adjacent Network0 (0.0%)
Attack Complexity
Low8 (100.0%)
High0 (0.0%)
Unknown0 (0.0%)
User Interaction
None5 (62.5%)
Unknown0 (0.0%)
Required3 (37.5%)
Privileges Required
Low1 (12.5%)
High2 (25.0%)
None5 (62.5%)
Unknown0 (0.0%)

Top CVEs

Signals from CVEs in this product scope (8 CVEs).

8 CVEs · Highest risk first

CVEPublishedCVSSRiskKEVExploit
In Bosch IP cameras, improper validation of the HTTP header allows an attacker to inject arbitrary HTTP headers through crafted URLs.
Jun 9, 20219.830NONO
A vulnerability in the web-based interface allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of another user (CSRF - Cross Site Request F
Aug 5, 20218.828NONO
An error in the URL handler Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the camera address can sen
Jun 9, 20216.122NONO
An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7
Jun 9, 20216.121NONO
A command injection vulnerability exists in Bosch IP cameras that allows an authenticated user with administrative rights to run arbitrary commands on the OS of the camera.
Dec 18, 20237.220NONO
An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and c
Jun 9, 20214.919NONO
Due to an error in the software interface to the secure element chip on Bosch IP cameras of family CPP13 and CPP14, the chip can be permanently damaged when enabling the Stream sec
Jun 15, 20236.518NONO
An information disclosure vulnerability was discovered in Bosch IP camera devices allowing an unauthenticated attacker to retrieve information (like capabilities) about the device
Dec 18, 20235.315NONO

Exploit Exposure

Signals from CVEs in this product scope (8 CVEs).

CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
0 CVEs
0.0% of CVEs· Bottom 1%

Social Chatter

Signals from CVEs in this product scope (8 CVEs).

Media Mentions

Signals from CVEs in this product scope (8 CVEs).

Top CNAs Publishing CVEs For Cpp13 Firmware

Top CWEs

Versions

VersionCVE CountAvg CVSSAvg EPSSKEVExploits
7.7616.10.5%00
7.7527.50.5%00