Cc612 Firmware
Vendor:
First CVE: Apr 27, 2022 · Active for 4 years
8
Total CVEs
More Total CVEs than 85% of tracked products
8.0
Avg CVEs / Year
Higher CVE frequency than 94% of tracked products
7.8
Avg CVSS
Higher Avg CVSS than 63% of tracked products
0.0%
KEV Rate
Bottom 1%
Trends Over Time
The number and severity of CVEs published that impact Cc612 Firmware over time
Volume of CVEsAvg CVSS Base Score
First CVE
Apr 27, 2022
4 years ago
Most Recent CVE
Apr 27, 2022
1,549 days ago
CVE Severity & Scoring
Cc612 Firmware8 CVEs
25%
63%
13%
All CVEs352,231 CVEs
45%
40%
11%
MediumHighCritical
Attack Vector
Local1 (12.5%)
Network7 (87.5%)
Unknown0 (0.0%)
Physical0 (0.0%)
Adjacent Network0 (0.0%)
Attack Complexity
Low8 (100.0%)
High0 (0.0%)
Unknown0 (0.0%)
User Interaction
None7 (87.5%)
Unknown0 (0.0%)
Required1 (12.5%)
Privileges Required
Low4 (50.0%)
High0 (0.0%)
None4 (50.0%)
Unknown0 (0.0%)
Top CVEs
Signals from CVEs in this product scope (8 CVEs).
8 CVEs · Highest risk first
| CVE | Published | CVSS | Risk | KEV | Exploit |
|---|---|---|---|---|---|
CVE-2021-34601CRITICAL In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh cred | Apr 27, 2022 | 9.8 | 29 | NO | NO |
CVE-2021-34602HIGH In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields | Apr 27, 2022 | 8.8 | 28 | NO | NO |
CVE-2021-34592HIGH In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields | Apr 27, 2022 | 8.8 | 28 | NO | NO |
CVE-2021-34588HIGH In Bender/ebee Charge Controllers in multiple versions are prone to unprotected data export. Backup export is protected via a random key. The key is set at user login. It is empty | Apr 27, 2022 | 8.6 | 27 | NO | NO |
CVE-2021-34591HIGH In Bender/ebee Charge Controllers in multiple versions are prone to Local privilege Escalation. An authenticated attacker could get root access via the suid applications socat, ip | Apr 27, 2022 | 7.8 | 25 | NO | NO |
CVE-2021-34589HIGH In Bender/ebee Charge Controllers in multiple versions are prone to an RFID leak. The RFID of the last charge event can be read without authentication via the web interface. | Apr 27, 2022 | 7.5 | 25 | NO | NO |
CVE-2021-34590MEDIUM In Bender/ebee Charge Controllers in multiple versions are prone to Cross-site Scripting. An authenticated attacker could write HTML Code into configuration values. These values ar | Apr 27, 2022 | 5.4 | 20 | NO | NO |
CVE-2021-34587MEDIUM In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable. | Apr 27, 2022 | 5.3 | 20 | NO | NO |
Exploit Exposure
Signals from CVEs in this product scope (8 CVEs).
CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
0 CVEs
0.0% of CVEs· Bottom 1%
Social Chatter
Signals from CVEs in this product scope (8 CVEs).
Media Mentions
Signals from CVEs in this product scope (8 CVEs).
Top CNAs Publishing CVEs For Cc612 Firmware
Top CWEs
Versions
No cataloged versions.