Apc

First CVE: Dec 31, 2000Active for: 26 yearsTotal CVEs: 14
29.1
VTI Score
Low

APC's vulnerability profile centers on power management and infrastructure monitoring products including PowerChute, network management cards, and switched rack PDUs that are widely deployed in data centers and enterprise facilities. The recurring exposure involves input-handling and authentication weaknesses—cross-site scripting, CSRF, improper authentication, and input validation flaws—that are characteristic of management interfaces, and vulnerabilities in this vendor's products tend toward public exploit availability. Current severity and exploitation counts are shown alongside this summary.

FAUCET AI Generated
14
Total CVEs
More Total CVEs than 94% of tracked vendors
0.1
Avg CVEs / Product / Year
More Avg CVEs / Product / Year than 1% of tracked vendors
6.0
Avg CVSS Score
Higher Avg CVSS Score than 29% of tracked vendors
0.0%
In CISA KEV
Bottom 1%

Trends Over Time

The number and severity of CVEs published that impact products developed by Apc over time

Volume of CVEsAvg CVSS Base Score
First CVE
Dec 31, 2000
25 years ago
Most Recent CVE
Aug 31, 2020
2,153 days ago

Products(11 total)

Top CVEs

Signals from CVEs in this vendor scope (14 CVEs).

14 CVEs · Highest risk first

CVEPublishedCVSSRiskKEVExploit
CVE-2004-0311HIGH
American Power Conversion (APC) Web/SNMP Management SmartSlot Card 3.0 through 3.0.3 and 3.21 are shipped with a default password of TENmanUFactOryPOWER, which allows remote attack
Nov 23, 200410.031NONO
CVE-2020-7526HIGH
Improper Input Validation vulnerability exists in PowerChute Business Edition (software V9.0.x and earlier) which could cause remote code execution when a script is executed during
Aug 31, 20208.826NONO
CVE-2001-0564MEDIUM
APC Web/SNMP Management Card prior to Firmware 310 only supports one telnet connection, which allows a remote attacker to create a denial of service via repeated failed logon attem
Aug 22, 20015.023NOYES
CVE-2000-1242HIGH
The HTTP service in American Power Conversion (APC) PowerChute uses a default username and password, which allows remote attackers to gain system access.
Dec 31, 20009.022NONO
CVE-2009-1798MEDIUM
Multiple cross-site scripting (XSS) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) de
Dec 28, 20094.321NOYES
CVE-2001-0040LOW
APC UPS daemon, apcupsd, saves its process ID in a world-writable file, which allows local users to kill an arbitrary process by specifying the target process ID in the apcupsd.pid
Feb 16, 20012.121NOYES
CVE-2007-6226HIGH
The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu 3.5.5 and aos 3.5.6, allows remote attackers to bypass authentication and
Dec 4, 20077.119NONO
CVE-2003-0099HIGH
Multiple buffer overflows in apcupsd before 3.8.6, and 3.10.x before 3.10.5, may allow attackers to cause a denial of service or execute arbitrary code, related to usage of the vsp
Mar 3, 20037.219NONO
CVE-2009-1797MEDIUM
Multiple cross-site request forgery (CSRF) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribut
Dec 28, 20096.818NONO
CVE-2011-4263MEDIUM
Cross-site scripting (XSS) vulnerability in Schneider Electric PowerChute Business Edition before 8.5 allows remote attackers to inject arbitrary web script or HTML via unspecified
Dec 7, 20114.316NONO
View all 14 CVEs →

CVE Severity & Scoring

Severity distribution of CVEs that affect this vendor's products14 CVEs
57%
36%
Severity distribution among all CVEs352,294 CVEs
45%
40%
11%
LowMediumHigh
Attack Vector
Local0 (0.0%)
Network1 (7.1%)
Unknown13 (92.9%)
Physical0 (0.0%)
Adjacent Network0 (0.0%)
Attack Complexity
Low1 (7.1%)
High0 (0.0%)
Unknown13 (92.9%)
User Interaction
None1 (7.1%)
Unknown13 (92.9%)
Required0 (0.0%)
Privileges Required
Low1 (7.1%)
High0 (0.0%)
None0 (0.0%)
Unknown13 (92.9%)

Exploit Exposure

Signals from CVEs in this vendor scope (14 CVEs).

CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
3 CVEs
21.4% of CVEs· 78th percentile

Social Chatter

An overview of all social media posts that mention a CVE ID that affects a product developed by Apc.

Media Mentions

Media articles that mention a CVE ID that affects a product developed by Apc — matched by CVE ID, not by vendor name.

Top CNAs Publishing CVEs For Apc's Products

View all 3 CNAs →

Top CWEs