Predictive Vulnerability Intelligence.

Product

  • Product
  • Pricing
  • Documentation

Company

  • About
  • Partnerships
  • Blog
  • Support

Legal

  • Terms
  • Privacy
  • Data Licensing

© 2026 FAUCET Technologies LLC. All rights reserved.

CWE-1263

Improper Physical Access Control

The product is designed with access restricted to certain information, but it does not sufficiently protect against an unauthorized actor with physical access to these areas.

13
Assigned CVEs
391st
Commonality Rank
6.6
Avg CVSS
0.0%
In CISA KEV

Volume and Severity of Assigned CVEs Over Time

Volume of CVEs assigned to CWE-1263 and their average CVSS base score over time.

Volume of CVEsAvg CVSS Base Score
First CVE
Oct 9, 2023
2 years ago
Most Recent CVE
May 7, 2026
78 days ago

Top CVEs Assigned This CWE

Top CVEs that have been assigned this CWE. A single CVE can have multiple CWE assignments, though many have just one.

13 CVEs · Highest risk first

CVEPublishedCVSSRiskKEVExploit
CVE-2024-48973CRITICAL
The debug port on the ventilator's serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which are unencrypted; see
Nov 14, 20249.325NONO
CVE-2025-4386MEDIUM
Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.​
May 7, 20266.824NONO
CVE-2025-8762MEDIUM
A vulnerability was found in INSTAR 2K+ and 4K 3.11.1 Build 1124. This issue affects some unknown processing of the component UART Interface. The manipulation leads to improper phy
Aug 13, 20256.823NONO
CVE-2022-32506MEDIUM
An issue was discovered on certain Nuki Home Solutions devices. An attacker with physical access to the circuit board could use the SWD debug features to control the execution of c
May 14, 20246.422NONO
CVE-2024-28326MEDIUM
Incorrect Access Control in ASUS RT-N12+ B1 and RT-N12 D1 routers allows local attackers to obtain root terminal access via the the UART interface.
Apr 26, 20246.822NONO
CVE-2023-38290HIGH
Certain software builds for the BLU View 2 and Sharp Rouvo V Android devices contain a vulnerable pre-installed app with a package name of com.evenwell.fqc (versionCode='9020801',
Apr 22, 20247.822NONO
CVE-2024-36438HIGH
eLinkSmart Hidden Smart Cabinet Lock 2024-05-22 has Incorrect Access Control and fails to perform an authorization check which can lead to card duplication and other attacks.
Jul 15, 20247.321NONO
CVE-2022-3728MEDIUM
A vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow
Oct 9, 20236.821NONO
CVE-2022-48182MEDIUM
A vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow
Oct 9, 20236.820NONO
CVE-2024-39512MEDIUM
An Improper Physical Access Control vulnerability in the console port control of Juniper Networks Junos OS Evolved allows an attacker with physical access to the device to get acce
Jul 10, 20246.619NONO
View all 13 CVEs →

CVE Severity & Scoring

This CWEGlobal (All CVEs)
0.0-0.9
1.0-1.9
2.0-2.9
3.0-3.9
10%
4.0-4.9
19%
5.0-5.9
62%
16%
6.0-6.9
15%
26%
7.0-7.9
11%
8.0-8.9
14%
9.0-10.0
unknown
CVSS Score Range

Exploit Exposure

Exploit activity across CVEs assigned to this CWE, including CVEs that carry other CWE assignments.

CISA KEV
0 CVEs
0.0% of CVEs· Bottom 1%
Metasploit
0 CVEs
0.0% of CVEs· Bottom 1%
Nuclei
0 CVEs
0.0% of CVEs· Bottom 1%
ExploitDB
0 CVEs
0.0% of CVEs· Bottom 1%

Social Chatter

Social posts that mention CVE IDs assigned to this CWE. This is assigned-CVE activity, not mentions of the CWE label itself.

Media Mentions

Media articles that mention CVE IDs assigned to this CWE. This is assigned-CVE coverage, not mentions of the CWE label itself.

Top Affected Vendors

Top Affected Products