CVE-2024-45472 is a memory corruption vulnerability affecting Siemens Teamcenter Visualization and Tecnomatix Plant Simulation, specifically when parsing specially crafted WRL files. An attacker could exploit this, potentially in conjunction with other vulnerabilities, to achieve arbitrary code execution within the context of the current process. This vulnerability has a CVSS score of 7.8 (High), indicating a significant risk due to its local attack vector, low attack complexity, and high impact on confidentiality, integrity, and availability. Currently, there is no evidence of active exploitation, public exploit code (Metasploit, Nuclei, ExploitDB), or significant community discussion surrounding this CVE.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
< 2302.0016CPE matchmatch criteria | cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* | ||
>= 2303.0000, < 2404.0005CPE matchmatch criteria | cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* |
CVSS version used by this source: 4.0
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
The average CVE in this peer group has 0.0 Twitter, 0.1 Reddit, 0.1 Bluesky, 0.0 Mastodon, and 0.2 GitHub mentions.
No media coverage found for this CVE.
The average CVE in this peer group has 0.3 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.