CVE-2022-25980 is a critical blind SQL injection vulnerability affecting all versions of Delta Electronics DIAEnergie prior to 1.8.02.004, specifically within the HandlerCommon.ashx component. With a CVSS score of 9.8, this vulnerability allows unauthenticated attackers to remotely inject arbitrary SQL queries, leading to full compromise of database contents, modification of data, and execution of system commands. While no public exploits or active exploitation have been observed, and community discussion is minimal, the high severity and ease of exploitation (AV:N/AC:L/PR:N/UI:N) warrant immediate patching.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
< 1.8.02.004CPE matchmatch criteria | cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:* |
CVSS version used by this source: 3.1
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
No social media mentions found for this CVE.
The average CVE in this peer group has 0.0 Twitter, 0.1 Reddit, 0.3 Bluesky, 0.3 Mastodon, and 2.4 GitHub mentions.
No media coverage found for this CVE.
The average CVE in this peer group has 0.3 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.