FAUCET Score

CVE-2022-24323 is a CWE-754 vulnerability affecting Schneider Electric EcoStruxure Process Expert (V2021 and prior) and EcoStruxure Control Expert (V15.0 SP1 and prior). An attacker can exploit this by intercepting and manipulating Modbus response data, leading to a disruption of communication between the Modicon controller and engineering software. With a CVSS score of 5.9 (MEDIUM), this vulnerability has a network attack vector and high attack complexity, but does not impact confidentiality or availability. There is currently no evidence of active exploitation, public exploit code (Metasploit, Nuclei, ExploitDB), or significant community discussion or media coverage.

Impacted Technologies

VendorProductVersion(s)CPE
< 15.0CPE matchmatch criteria
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*
15.0CPE matchmatch criteria
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*
15.0CPE matchmatch criteria
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*
<= 2021CPE matchmatch criteria
cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*

CVSS Data

CVSS version used by this source: 3.1

5.3MEDIUM

CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H

Attack Vector
NETWORK
Attack Complexity
HIGH
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
HIGH
Exploitability Score
1.6
Impact Score
3.6
CvssVersion
3.1

Exploit Intelligence

EPSS Score
0.85%
Probability of exploitation in next 30 days
EPSS Percentile
54.4%
Percentile rank of EPSS score among Peer Group
As of 2026-07-28
Model: v2026.06.15
This CVE's current EPSS score of 0.0085 is in the 12th percentile among its peer group of 19,958 CVEs.

Social Chatter

The average CVE in this peer group has 0.0 Twitter, 0.0 Reddit, 0.0 Bluesky, 0.0 Mastodon, and 0.2 GitHub mentions.

Media Mentions

No media coverage found for this CVE.

The average CVE in this peer group has 0.0 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.

Remediation

Remediation records are not available for this CVE.

References

download.schneider-electric.com / files
Vendor Advisory