CVE-2018-7815 describes a Type Confusion vulnerability (CWE-843) in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) within the c3core.dll component. This flaw allows for remote code execution when a specially crafted GD1 file is parsed. With a CVSS v3 score of 7.8 (High), this vulnerability requires user interaction (UI:R) and local access (AV:L), but has a low attack complexity (AC:L) and no privileges required (PR:N), leading to high impacts on confidentiality, integrity, and availability. There is no evidence of active exploitation, public exploit code (Metasploit, Nuclei, ExploitDB), or significant community discussion or media coverage, indicating a low current threat landscape.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
2.0CPE matchmatch criteria | cpe:2.3:a:schneider-electric:guicon:2.0:*:*:*:*:*:*:* |
CVSS version used by this source: 3.0
CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
The average CVE in this peer group has 0.0 Twitter, 0.1 Reddit, 0.1 Bluesky, 0.0 Mastodon, and 0.2 GitHub mentions.
No media coverage found for this CVE.
The average CVE in this peer group has 0.3 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.