CVE-2018-7235 is a high-severity vulnerability affecting Schneider Electric's Pelco Sarix Professional cameras with firmware versions prior to 3.29.67. This flaw allows an unauthenticated attacker to download arbitrary system files due to insufficient validation of shell metacharacters in a specific configuration parameter. The vulnerability has a CVSS score of 7.5, indicating a network-based attack with low complexity and high confidentiality impact, but no integrity or availability impact. There is currently no public exploit code available, nor any indication of active exploitation or significant community discussion surrounding this CVE.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
< 3.29.67CPE matchmatch criteria | cpe:2.3:o:schneider-electric:mps110-1_firmware:*:*:*:*:*:*:*:* | ||
< 3.29.67CPE matchmatch criteria | cpe:2.3:o:schneider-electric:imps110-1er_firmware:*:*:*:*:*:*:*:* | ||
< 3.29.67CPE matchmatch criteria | cpe:2.3:o:schneider-electric:ibps110-1er_firmware:*:*:*:*:*:*:*:* | ||
< 3.29.67CPE matchmatch criteria | cpe:2.3:o:schneider-electric:imp1110-1_firmware:*:*:*:*:*:*:*:* | ||
< 3.29.67CPE matchmatch criteria | cpe:2.3:o:schneider-electric:imp1110-1e_firmware:*:*:*:*:*:*:*:* |
CVSS version used by this source: 3.1
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
The average CVE in this peer group has 0.0 Twitter, 0.0 Reddit, 0.1 Bluesky, 0.1 Mastodon, and 0.4 GitHub mentions.
No media coverage found for this CVE.
The average CVE in this peer group has 0.1 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.