CVE-2018-18976 describes a Direct Object Reference (IDOR) vulnerability in the Ascensia Contour NEXT ONE application for iOS and Android, affecting versions prior to January 15, 2019. An attacker could exploit this to retrieve encrypted medical information of any user on the Ascensia cloud platform by iterating through user ID values. The vulnerability has a CVSS score of 5.3 (Medium), indicating a network-based attack with low complexity, requiring no privileges or user interaction, and resulting in a low impact on confidentiality. There is no evidence of active exploitation, public exploit code (Metasploit, Nuclei, ExploitDB), or significant community discussion or media coverage surrounding this CVE.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
< 2.4.30CPE matchmatch criteria | cpe:2.3:a:ascensia:contour_diabetes:*:*:*:*:*:iphone_os:*:* | ||
< 2.5.0CPE matchmatch criteria | cpe:2.3:a:ascensia:contour_diabetes:*:*:*:*:*:android:*:* |
CVSS version used by this source: 3.0
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
The average CVE in this peer group has 0.0 Twitter, 0.0 Reddit, 0.1 Bluesky, 0.0 Mastodon, and 0.4 GitHub mentions.
No media coverage found for this CVE.
The average CVE in this peer group has 0.0 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.