CVE-2015-3977

20
FAUCET Score

CVE-2015-3977 describes a buffer overflow vulnerability in Schneider Electric IMT25 Magnetic Flow DTM versions prior to 1.500.004, specifically impacting the HART Protocol. This flaw allows remote authenticated attackers to execute arbitrary code or trigger a denial of service through memory corruption by sending a specially crafted HART reply. With a CVSS score of 7.7, it presents a high severity risk due to its network-adjacent attack vector, low complexity, and complete impact on confidentiality, integrity, and availability. There is no evidence of active exploitation, public exploit code (Metasploit, Nuclei, ExploitDB), or significant community discussion or media coverage surrounding this vulnerability.

Impacted Technologies

VendorProductVersion(s)CPE
<= 1.500.000CPE matchmatch criteria
cpe:2.3:o:schneider-electric:imt25_magnetic_flow_dtm:*:*:*:*:*:*:*:*

CVSS Data

CVSS version used by this source: 2.0

7.7HIGH

AV:A/AC:L/Au:S/C:C/I:C/A:C

Confidentiality Impact
COMPLETE
Integrity Impact
COMPLETE
Availability Impact
COMPLETE
Access Vector
ADJACENT_NETWORK
Access Complexity
LOW
Authentication
SINGLE
Exploitability Score
5.1
Impact Score
10.0
CvssVersion
2.0

Exploit Intelligence

EPSS Score
1.08%
Probability of exploitation in next 30 days
EPSS Percentile
61.6%
Percentile rank of EPSS score among Peer Group
As of 2026-07-27
Model: v2026.06.15
This CVE's current EPSS score of 0.0108 is in the 64th percentile among its peer group of 554 CVEs.

Social Chatter

No social media mentions found for this CVE.

The average CVE in this peer group has 0.0 Twitter, 0.1 Reddit, 0.2 Bluesky, 0.1 Mastodon, and 0.2 GitHub mentions.

Media Mentions

No media coverage found for this CVE.

The average CVE in this peer group has 0.3 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.

Remediation

Remediation records are not available for this CVE.

References

download.schneider-electric.com / files
Vendor Advisory
ics-cert.us-cert.gov / advisories/ICSA-15-223-01
Third Party AdvisoryUS Government Resource