CVE-2013-3957 describes a critical SQL injection vulnerability found in the login screen of Siemens WinCC (versions prior to 7.2 Update 1) and SIMATIC PCS7 (8.0 SP1 and earlier). This flaw allows unauthenticated remote attackers to execute arbitrary SQL commands, potentially leading to data compromise, integrity issues, and denial of service. With a CVSS score of 7.5, it is a high-severity vulnerability that is easily exploitable over the network with low attack complexity. Despite its severity, there is no evidence of active exploitation, public exploit code, or significant community discussion or media coverage.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
<= 8.0CPE matchmatch criteria | cpe:2.3:a:siemens:simatic_pcs7:*:sp1:*:*:*:*:*:* | ||
8.0CPE matchmatch criteria | cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:* | ||
<= 7.2CPE matchmatch criteria | cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:* | ||
7.0CPE matchmatch criteria | cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:* | ||
7.0CPE matchmatch criteria | cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:* |
CVSS version used by this source: 2.0
AV:N/AC:L/Au:N/C:P/I:P/A:P
No social media mentions found for this CVE.
The average CVE in this peer group has 0.0 Twitter, 0.0 Reddit, 0.1 Bluesky, 0.1 Mastodon, and 0.4 GitHub mentions.
No media coverage found for this CVE.
The average CVE in this peer group has 0.1 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.