CVE-2012-3030 describes an insufficient access control vulnerability in Siemens WinCC 7.0 SP3 and earlier, including its use in SIMATIC PCS7. This flaw allows remote attackers to directly request and read sensitive log or configuration files stored under the web root. The vulnerability has a CVSS score of 5.0, indicating a medium severity risk due to its network-based attack vector and low complexity, potentially leading to information disclosure. There is no evidence of active exploitation, public exploit code (Metasploit, Nuclei, ExploitDB), or significant community discussion or media coverage surrounding this CVE.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
8.0CPE matchmatch criteria | cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:* | ||
<= 7.0CPE matchmatch criteria | cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:* | ||
5.0CPE matchmatch criteria | cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:* | ||
5.0CPE matchmatch criteria | cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:* | ||
6.0CPE matchmatch criteria | cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:* |
CVSS version used by this source: 2.0
AV:N/AC:L/Au:N/C:P/I:N/A:N
The average CVE in this peer group has 0.0 Twitter, 0.0 Reddit, 0.1 Bluesky, 0.0 Mastodon, and 0.4 GitHub mentions.
No media coverage found for this CVE.
The average CVE in this peer group has 0.0 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.