CVE-2012-1802

25
FAUCET Score

CVE-2012-1802 describes a buffer overflow vulnerability in the embedded web server of several Siemens Scalance X Industrial Ethernet switch models, including X414-3E, X308-2M, X-300EEC, XR-300, and X-300, all running firmware versions prior to 3.7.1 or 3.7.2. This flaw allows unauthenticated remote attackers to trigger a denial of service, causing a device reboot, and potentially execute arbitrary code by sending a malformed URL. With a CVSS score of 7.8, this vulnerability is considered high severity due to its network-based attack vector and low attack complexity, requiring no authentication. Despite its age, there is no evidence of active exploitation, publicly available exploit code (Metasploit, Nuclei, ExploitDB), or significant community discussion or media coverage.

Impacted Technologies

VendorProductVersion(s)CPE
<= 3.7.0CPE matchmatch criteria
cpe:2.3:a:siemens:scalance_x414-3e_firmware:*:*:*:*:*:*:*:*
1.2.2CPE matchmatch criteria
cpe:2.3:a:siemens:scalance_x414-3e_firmware:1.2.2:*:*:*:*:*:*:*
2.1.1CPE matchmatch criteria
cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.1.1:*:*:*:*:*:*:*
2.2.0CPE matchmatch criteria
cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.2.0:*:*:*:*:*:*:*
2.3.2CPE matchmatch criteria
cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.2:*:*:*:*:*:*:*

CVSS Data

CVSS version used by this source: 2.0

7.8HIGH

AV:N/AC:L/Au:N/C:N/I:N/A:C

Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
COMPLETE
Access Vector
NETWORK
Access Complexity
LOW
Authentication
NONE
Exploitability Score
10.0
Impact Score
6.9
CvssVersion
2.0

Exploit Intelligence

EPSS Score
6.12%
Probability of exploitation in next 30 days
EPSS Percentile
92.7%
Percentile rank of EPSS score among Peer Group
As of 2026-07-25
Model: v2026.06.15
This CVE's current EPSS score of 0.0612 is in the 88th percentile among its peer group of 51,485 CVEs.

Social Chatter

The average CVE in this peer group has 0.0 Twitter, 0.0 Reddit, 0.1 Bluesky, 0.1 Mastodon, and 0.4 GitHub mentions.

Media Mentions

No media coverage found for this CVE.

The average CVE in this peer group has 0.1 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.

Remediation

Remediation records are not available for this CVE.

References

osvdb.org / 81032
siemens.com / corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf
Vendor Advisory
us-cert.gov / control_systems/pdf/ICSA-12-102-04.pdf
US Government Resource