CVE-2025-35031 affects Medical Informatics Engineering Enterprise Health, where the user's current session token is inadvertently included in debug output. An attacker could leverage social engineering to trick a user into sharing this output, enabling session hijacking and user impersonation. With a CVSS score of 5.5 (Medium), this vulnerability requires user interaction (UI:R) and local access (AV:L), but could lead to high integrity impact (I:H). There is currently no evidence of active exploitation, public exploit code, or significant community discussion, and it is not listed in CISA's KEV catalog. A fix for this issue was released on April 8, 2025.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
rc202403CPE matchmatch criteria | cpe:2.3:a:mieweb:enterprise_health:rc202403:*:*:*:*:*:*:* | ||
rc202409CPE matchmatch criteria | cpe:2.3:a:mieweb:enterprise_health:rc202409:*:*:*:*:*:*:* | ||
rc202503CPE matchmatch criteria | cpe:2.3:a:mieweb:enterprise_health:rc202503:*:*:*:*:*:*:* |
CVSS version used by this source: 4.0
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
The average CVE in this peer group has 0.0 Twitter, 0.0 Reddit, 0.0 Bluesky, 0.0 Mastodon, and 0.1 GitHub mentions.
No media coverage found for this CVE.
The average CVE in this peer group has 0.1 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.