CVE-2024-30206 is a high-severity vulnerability affecting multiple versions of Siemens SIMATIC RTLS Locating Manager. The flaw, categorized as CWE-494 (Improper Download of Updates), allows an unauthenticated remote attacker to alter update files in transit due to insufficient integrity checks, potentially leading to the installation of malicious code by an authorized user. This attack requires the adversary to intercept and modify network communication between the server and client. The vulnerability has a CVSS score of 8.8 (HIGH), indicating a high impact on confidentiality, integrity, and availability, with a network attack vector and low attack complexity, but requiring user interaction. Despite its severity, there is currently no evidence of active exploitation, no public exploit code available (Metasploit, Nuclei, ExploitDB), and minimal community discussion or media coverage. The EPSS score is low, suggesting a low probability of exploitation in the wild.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
>= 0, < V3.0.1.1CPE match | cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* |
CVSS version used by this source: 4.0
CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
The average CVE in this peer group has 0.0 Twitter, 0.1 Reddit, 0.3 Bluesky, 0.1 Mastodon, and 0.1 GitHub mentions.
No media coverage found for this CVE.
The average CVE in this peer group has 0.3 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.