CVE-2019-18342 is a critical vulnerability affecting all versions of Siemens Control Center Server (CCS) prior to V1.5.0. It stems from the SFTP service (port 22/tcp) not properly limiting its capabilities, allowing an unauthenticated remote attacker to read or delete arbitrary files and access other resources on the server when combined with CVE-2019-18341. With a CVSS score of 9.9 (CRITICAL), this vulnerability presents a severe risk due to its network-based attack vector, low attack complexity, and high impact on confidentiality, integrity, and availability. While there is no known active exploitation or public exploit code (Metasploit, Nuclei, ExploitDB), the vulnerability has garnered significant community discussion and media coverage, indicating awareness and potential for future exploitation.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
< 1.5.0CPE matchmatch criteria | cpe:2.3:a:siemens:control_center_server:*:*:*:*:*:*:*:* |
CVSS version used by this source: 3.1
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
The average CVE in this peer group has 0.0 Twitter, 0.1 Reddit, 1.0 Bluesky, 0.5 Mastodon, and 1.6 GitHub mentions.
The average CVE in this peer group has 0.3 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.