CVE-2018-18630 is a high-severity vulnerability affecting McKesson Cardiology product versions 13.x and 14.x, as well as various Change Healthcare Cardiology and Horizon Cardiology products. The flaw stems from insecure file permissions in the default installation, allowing a local attacker to execute arbitrary code. With a CVSS score of 7.8, this vulnerability has a low attack complexity and requires local privileges, but can lead to high impact on confidentiality, integrity, and availability. There is no evidence of active exploitation, public exploit code (Metasploit, Nuclei, ExploitDB), or significant community discussion or media coverage surrounding this CVE.
| Vendor | Product | Version(s) | CPE |
|---|---|---|---|
>= 12.0, <= 12.2CPE matchmatch criteria | cpe:2.3:o:mckesson:horizon_cardiology_firmware:*:*:*:*:*:*:*:* | ||
11.0CPE matchmatch criteria | cpe:2.3:o:mckesson:horizon_cardiology_firmware:11.0:*:*:*:*:*:*:* | ||
13.0CPE matchmatch criteria | cpe:2.3:o:mckesson:cardiology_firmware:13.0:*:*:*:*:*:*:* | ||
14.0CPE matchmatch criteria | cpe:2.3:o:mckesson:cardiology_firmware:14.0:*:*:*:*:*:*:* | ||
14.1.0CPE matchmatch criteria | cpe:2.3:o:changehealthcare:cardiology_firmware:14.1.0:*:*:*:*:*:*:* |
CVSS version used by this source: 3.1
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
The average CVE in this peer group has 0.0 Twitter, 0.1 Reddit, 0.2 Bluesky, 0.1 Mastodon, and 0.2 GitHub mentions.
No media coverage found for this CVE.
The average CVE in this peer group has 0.3 InfoSec Media, 0.0 Vendor Blog, and 0.0 Security Researcher mentions.
Remediation records are not available for this CVE.